Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space, 1/2" per pole. UL Listed, HACR rated. 15 and 20 amp SWD, switching duty rated, suitable for 120 volt fluorescent lighting loads. 15 to 25 amp #14 - 8 Cu or #12 - 8 Al AWG wire, 30 to 50 amp #8 - 4 Cu or #8 - 2 Al AWG wire. 3-9/32" height x 1/2" width x 2-3/8" depth. 120/240 volt; 10,000 AIR.
|PLUG-IN - SINGLE POLE
|TYPE THQP
|FACTORY INSTALLED LUGS
|Brand:"Q LINE"
|Amp Rating=50
Interchangeable, will replace: Bryant, Challenger and Westinghouse. Type BR. 120/240 volt. 10 kAIC, 10,000 AIR. 2 spaces, 2" per breaker.
|PLUG-ON - DOUBLE POLE
|TYPE BR - COMMON TRIP
|Amp Rating=20
Interchangeable, will replace: Bryant, Challenger and Westinghouse. Type BR. 120/240 volt. 10 kAIC, 10,000 AIR. 2 spaces, 2" per breaker.
|PLUG-ON - DOUBLE POLE
|TYPE BR - COMMON TRIP
|Amp Rating=30
Interchangeable, will replace: Bryant, Challenger and Westinghouse. Type BR. 120/240 volt. 10 kAIC, 10,000 AIR. 2 spaces, 2" per breaker.
|PLUG-ON - DOUBLE POLE
|TYPE BR - COMMON TRIP
|Amp Rating=40
Interchangeable, will replace: Bryant, Challenger and Westinghouse. Type BR. 120/240 volt. 10 kAIC, 10,000 AIR. 2 spaces, 2" per breaker.
|PLUG-ON - DOUBLE POLE
|TYPE BR - COMMON TRIP
|Amp Rating=50
Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. Type THQL - 1" per pole. May be used, when marked to accept, with American Switch, Arrow Hart, Bryant, General Switch, GTE, Sylvania, most ITE, Murray, Westinghouse Type BR, Challenger, Crouse-Hinds. 15 to 30 amp 14 - 8 Cu or 12 - 8 Al AWG wire, 35 to 60 amp 8 - 3 Cu or 8 - 2 Al AWG wire. UL Listed, HACR rated. 1" module, 120/240 volt; 10,000 AIR.
|PLUG-IN - SINGLE POLE
|TYPE THQL
|FACTORY INSTALLED LUGS
|Brand:"Q LINE"
|Amp Rating=20
Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. Type THQL - 1" per pole. May be used, when marked to accept, with American Switch, Arrow Hart, Bryant, General Switch, GTE, Sylvania, most ITE, Murray, Westinghouse Type BR, Challenger, Crouse-Hinds. 15 to 30 amp 14 - 8 Cu or 12 - 8 Al AWG wire, 35 to 60 amp 8 - 3 Cu or 8 - 2 Al AWG wire. UL Listed, HACR rated. 1" module, 120/240 volt; 10,000 AIR.
|PLUG-IN - SINGLE POLE
|TYPE THQL
|FACTORY INSTALLED LUGS
|Brand:"Q LINE"
|Amp Rating=30
Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. Type THQL - 1" per pole. May be used, when marked to accept, with American Switch, Arrow Hart, Bryant, General Switch, GTE, Sylvania, most ITE, Murray, Westinghouse Type BR, Challenger, Crouse-Hinds. 15 to 30 amp 14 - 8 Cu or 12 - 8 Al AWG wire, 35 to 60 amp 8 - 3 Cu or 8 - 2 Al AWG wire. UL Listed, HACR rated. 1" module, 120/240 volt; 10,000 AIR.
|PLUG-IN - SINGLE POLE
|TYPE THQL
|FACTORY INSTALLED LUGS
|Brand:"Q LINE"
|Amp Rating=40
Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. Type THQL - 1" per pole. May be used, when marked to accept, with American Switch, Arrow Hart, Bryant, General Switch, GTE, Sylvania, most ITE, Murray, Westinghouse Type BR, Challenger, Crouse-Hinds. 15 to 30 amp 14 - 8 Cu or 12 - 8 Al AWG wire, 35 to 60 amp 8 - 3 Cu or 8 - 2 Al AWG wire. UL Listed, HACR rated. 1" module, 120/240 volt; 10,000 AIR.
|PLUG-IN - SINGLE POLE
|TYPE THQL
|FACTORY INSTALLED LUGS
|Brand:"Q LINE"
|Amp Rating=50